Which of the following applications would be a violation of the nec

1. Which of the following applications would be a violation of the NEC for an installation using PVC conduit?

A. Behind walls

B. Laundry room

C. Supporting a light fixture

D. Underground

 

2. Which of the following raceways is permitted for installation in cinder fill without additional protection?

A. IMC

B. RMC

C. EMT

D. PVC

 

3. Two electricians are discussing different wiring methods. Electrician A says that because the conduit body indicates its capacity in cubic inches, splices can be used within the conduit body. Electrician B says that the conductors must be installed before the raceway is complete. Which of the following statements is correct?

A. Only Electrician A is correct.

B. Only Electrician B is correct.

C. Both electricians are correct.

D. Neither electrician is correct.

 

4. Which of the following is not an acceptable condition for an installation using FMC (Greenfield) raceway?

A. With supports every 3½ feet

B. With angle connectors behind drywall

C. With supports 8″ on either side of each box

D. With three 90° bends between two pull points

 

 

5. What minimum-size, square metal box is required for six, 12 AWG, three, 10 AWG, and 4, 8 AWG conductors spliced in this box? The box has two internal AC cable clamps.

A. 4 × 1½

B. 4 11/16 × 2⅛

C. 4 11/16 × 1½

D. 4 × 2½

 

6. A pull box used for a straight pull is part of an installation where three 2-inch conduit raceways are connected on both side of the pull box. What is the minimum length required for the pull box per the NEC?

A. 8″

B. 24″

C. 16″

D. 48″

 

 

7. According to the NEC, only a _______ wiring method can be used for a surface extension from the cover of a concealed box (provided the cover is unlikely to fall off), and the wiring method must include an equipment-grounding conductor.

A. rigid

B. solid

C. flexible

D. core

 

8. Which of the following boxes commonly used in electrical work is used at a point in the circuit where current is applied to utilization equipment?

A. Device box

B. Pull box

C. Junction box

D. Handhole box

 

9. Two electricians are discussing bonding circuits. Electrician A says that to bond an isolated ground circuit more, you can add reducing washers to improve the low impedance path. Electrician B says that in a hazardous location, the bonding can use a bonding bushing with a jumper. Which of the following statements is correct?

A. Neither electrician is correct.

B. Only Electrician A is correct.

C. Only Electrician B is correct.

D. Both electricians are correct.

 

10. A vertical raceway requires intermediate cable supports. If the raceway carries 3/0 AWG copper conductors, at what distance in meters will the supports be required?

A. 80

B. 60

C. 25

D. 30

 

11. What is the maximum number of No. 6 AWG conductors that can be installed in a 4″ × 2⅛″ round metal box if there are no clamps, fittings, devices or grounding conductors in the box?

A. 4

B. 8

C. 6

D. 3

 

12. What minimum-size, 411∕16″ square box is required for four 12 AWG, four 10 AWG, and four 8 AWG conductors spliced in this box?

A. 411∕16″ × 2⅛″

B. 411∕16″ × 1¼″

C. 411∕16″ × 2¼″

D. 411∕16″ × 1½″

 

 

 

 

13. What is the minimum length of a pull box connected to three, 2-inch diameter raceways?

A. 16 inches

B. 48 inches

C. 12 inches

D. 32 inches

 

14. What is the bending radius for 1½-inch diameter, corrugated MC cable?

A. 10.5 inches

B. 18.0 inches

C. 22.5 inches

D. 15.0 inches

 

15. Flexible metal conduit is permitted for grounding by the NEC if the length in any ground return path is not over 6 feet, and the circuit conductors are protected by an overcurrent protection device that does not exceed _______ amperes.

A. 15

B. 30

C. 20

D. 60

16. What is the required bend radius for service entrance cable, 3-conductor, 3/0 AWG, approximately 1inch in diameter?

A. 15″

B. 5″

C. 1″

D. 3″

17. Where resistance to ground of a single made-electrode exceeds 25 ohms,

A. the electrode can be omitted.

B. no additional electrodes are required.

C. one additional electrode must be added.

D. additional electrodes must be added until the resistance to ground is lower than 25 ohms.

 

18. Two electricians are discussing grounding. Electrician A says that 6″ of an 8′ rod or pipe electrode is allowed to extend above the finished grade. Electrician B says that a “made” grounding electrode constructed from copper rod that is ⅝″ in diameter and 100″ long is acceptable per the NEC. Which of the following statements is correct?

A. Only Electrician A is correct.

B. Neither electrician is correct.

C. Both electricians are correct.

D. Only Electrician B is correct.

 

19. Which of the following is an acceptable installation for the use of Type NM (Romex) cable?

A. Embedded in concrete

B. Service entrance cable

C. Detached garage of two-family residence

D. Wet/damp locations

20. Two electricians are discussing underground installation of raceways. Electrician A says that cables installed under a building must be in a raceway. Electrician B says that nonmetallic raceways placed under a two-family driveway must have at least 18 inches from the top of the raceway to the surface of the finished grade. Which of the following statements is correct?

A. Neither electrician is correct.

B. Both electricians are correct.

C. Only Electrician B is correct.

D. Only Electrician A is correct.

Calculate Your Essay Price
(550 words)

Approximate price: $22

Calculate the price of your order

550 words
We'll send you the first draft for approval by September 11, 2018 at 10:52 AM
Total price:
$26
The price is based on these factors:
Academic level
Number of pages
Urgency
Basic features
  • Free title page and bibliography
  • Unlimited revisions
  • Plagiarism-free guarantee
  • Money-back guarantee
  • 24/7 support
On-demand options
  • Writer’s samples
  • Part-by-part delivery
  • Overnight delivery
  • Copies of used sources
  • Expert Proofreading
Paper format
  • 275 words per page
  • 12 pt Arial/Times New Roman
  • Double line spacing
  • Any citation style (APA, MLA, Chicago/Turabian, Harvard)

Our guarantees

Delivering a high-quality product at a reasonable price is not enough anymore.
That’s why we have developed 5 beneficial guarantees that will make your experience with our service enjoyable, easy, and safe.

Money-back guarantee

You have to be 100% sure of the quality of your product to give a money-back guarantee. This describes us perfectly. Make sure that this guarantee is totally transparent.

Read more

Zero-plagiarism guarantee

Each paper is composed from scratch, according to your instructions. It is then checked by our plagiarism-detection software. There is no gap where plagiarism could squeeze in.

Read more

Free-revision policy

Thanks to our free revisions, there is no way for you to be unsatisfied. We will work on your paper until you are completely happy with the result.

Read more

Privacy policy

Your email is safe, as we store it according to international data protection rules. Your bank details are secure, as we use only reliable payment systems.

Read more

Fair-cooperation guarantee

By sending us your money, you buy the service we provide. Check out our terms and conditions if you prefer business talks to be laid out in official language.

Read more